AEGIS
Aquatrac’s innovative design offers both on/off and variable frequency pump control with ppm setpoints.
AQUATRAC’s AEGIS controller provides the latest in technology and is the perfect economical solution for process, cooling, boiler and waste water treatment applications.
AEGIS Advantages & Benefits
Variable Frequency Pump Controls:
Accurate and precise chemical feed using
pulse outputs. Can also select On/Off control if desired.
Data Logging:
Data history provides sensor minimum, maximum and
average. Also records pump run times, pump feed
volume, calculated drum levels, water meter volume,
tower run time.
Aquatrac Exclusive Thermal Flow Switch:
Aquatrac’s exclusive design does not require user
adjustment or calibration. Operates on 1GPM flow rate
with no moving parts.
ProMinent Pump Integration:
Select from popular ProMinent pump models built into
the Aegis programming for accurate ppm feed, tank
level and feed volume.
Feed Inhibitor using ppm setpoints:
Accurate and precise inhibitor feed by simply
inputting desired ppm level based on inhibitor chemistry.
Use with make-up water meter.
Plug and Play Onsite Upgrades:
The Aegis features Plug and Play technology
allowing the user to perform simple onsite
upgrades and scalability.
Program chemical feed based on drop tests: Program chemical feed by entering results of system testing using ppm, ml or drop tests. Enter the new value and desired alarm setpoints for worry-free chemical feed and control.
Drum Level Alarms Provide low level alarms without the use of level sensors. The Aegis calculates volume fed and subtracts from tank inventory.
Communications: Ethernet, MODBUS, land phone line
Check out a demo for yourself at http://aegis.aquatrac.com
- Inhibitor Feed Using PPM Setpoints
- Volumetric Timer Controls
- Relay Mirroring
- Optional Ethernet Communications
- MODBUS
- Industrial and Commercial Series
- Plug and Play Upgrades
- Works with Trackster 3 Software
- Aquatrac Thermal Flow Switch
- Easily Upgradeable with Plug-in Modules
- Fully Programmable
- Flexibility Allows You To Combine Multiple Boilers and Cooling Towers in One Controller
- Built in Ethernet with user definable static IP address
Click an image for a larger view
User Manuals |
2. |
|
|
Manual Aegis Português.pdf |
Aegis - Controlador para Tratamento de Água
back to Literature Categories |
7. |
|
|
S_ATP-CP-OX-T1-CTF.pdf |
Startup guide for Aegis controller ATP-CP-OX-T1-CTF. .
back to Literature Categories |
8. |
|
|
S_ATP-CO-T2-CTF.pdf |
Startup guide for Aegis controller ATP-CO-T2-CTF. .
back to Literature Categories |
9. |
|
|
S_ATP-CO-OX-T2-CTF.pdf |
Startup guide for Aegis controller ATP-CO-OX-T2-CTF. .
back to Literature Categories |
10. |
|
|
S_ABP-B2-T3.pdf |
Startup guide for Aegis controller ABP-B2-T3.
back to Literature Categories |
11. |
|
|
S_ABP-B1-T3.pdf |
Startup guide for Aegis controller ABP-B1-T3.
back to Literature Categories |
12. |
|
|
Aegis_User.pdf |
Installation and Operating manual for the Aegis controller. Discusses Day-To-Day operation; Chemical Feed Controls; Biocides; Sensors; Measuring Volume; Bleed; Blowdown; Flowswitches; Frequency Control; 4-20mA; System Setting.
back to Literature Categories |
13. |
|
|
Aegis_Modem.pdf |
User Manual for how to setup your computer for Modem communications with an Aegis controller.
back to Literature Categories |
14. |
|
|
Aegis_Browser.pdf |
User Manual for how to operate the Aegis using the Browser interface.
back to Literature Categories |
33. |
|
|
Driver_B.pdf |
User Manual for the 'B Driver' card (The 'B Driver' card measures one or two Conductivity sensors). Discusses Installation, Configuration, and Specification on the B Driver.
back to Literature Categories |
34. |
|
|
Driver_CI.pdf |
User Manual for the 'CI Driver' card (The 'CI Driver' card measures two 4-20mA Current Loop Inputs). Discusses Installation, Configuration, and Specification on the CI Driver.
back to Literature Categories |
35. |
|
|
Driver_CR.pdf |
User Manual for the 'CR Driver' card (The 'CR Driver' measures one or two corrosion rates using Linear Polarization Resistance). Discusses Installation, Configuration, and Specification on the CR Driver.
back to Literature Categories |
36. |
|
|
Driver_CT.pdf |
User Manual for the 'CT Driver' card (The 'CT Driver' measures conductivity and temperature, connecting to a single immersed sensor). Discusses Installation, Configuration, and Specification on the CT Driver.
back to Literature Categories |
37. |
|
|
Driver_IO.pdf |
User Manual for the 'IO Driver' card (The 'IO Driver' provides one or two, DC isolated, loop powered 4-20mA outputs). Discusses Installation, Configuration, and Specification on the IO Driver.
back to Literature Categories |
38. |
|
|
Driver_OP.pdf |
User Manual for the 'OP Driver' card (The 'OP Driver' measures ORP and pH sensors). Discusses Installation, Configuration, and Specification on the OP Driver.
back to Literature Categories |
39. |
|
|
Driver_PT.pdf |
User Manual for the 'PT Driver' card (The 'PT Driver' measures a pH sensor and a temperature using a platinum RTD.). Discusses Installation, Configuration, and Specification on the PT Driver.
back to Literature Categories |
40. |
|
|
Driver_RS.pdf |
User Manual for the 'RS Driver' card (The 'RS Driver' measures flow rate using a turbine or paddlewheel water meter and may be configured to control the stroke rate of a solenoid drive chemical feed pump based on the measured flow rate). Discusses Installation, Configuration, and Specification on the RS Driver.
back to Literature Categories |
41. |
|
|
Driver_OP_Ext.pdf |
User Manual for the 'OP_Ext Driver' card (The 'OP_Ext Driver' measures a remote pH sensor connected to a Multiflex, Aegis, or SmartSeries (Flex/AS) controller). Discusses Installation, Configuration, and Specification on the OP_Ext Driver.
back to Literature Categories |
 |
Application Notes |
1. |
|
|
HowToSetupComputerIPAddress.pdf |
(Adobe PDF) Instructions on how to configure the IP Address of your computer so that you can communicate (via web browser and/or Trackster) with a controller.
back to Literature Categories |
4. |
|
|
AN010-01_Snubbers.pdf |
Application Note that explains what a ‘snubber’ is and why they are required on some blowdown valves to prevent controller resets and controller power relay failures.
back to Literature Categories |
5. |
|
|
AN010-02_Sensor_PM.pdf |
Application Note on Preventative Maintenance for Cooling Tower Sensors. Lists sensors with recommended calibration, cleaning and replacement schedules
back to Literature Categories |
6. |
|
|
AN010-03_ORP_Sensor_Test.pdf |
Application Note on ORP Sensors Electrical Testing. Details electrical testing to identify ORP sensor failures
back to Literature Categories |
12. |
|
|
AN010-09_Paddle_Flowswitch.pdf |
Application Note which Provides source and part number information for the older, 1/2in NPT paddle type flow switches Aquatrac Part Number A261400; used in Smart3 and earlier version of S1T series controllers.
back to Literature Categories |
16. |
|
|
AN010-16_4-20mA_Troubleshooting.pdf |
Application Note on Current Loop Function and Troubleshooting. Discusses the troubleshooting self powered, DC isolated current loops.
back to Literature Categories |
17. |
|
|
AN010-17_4-20mA_Loop_Calib.pdf |
Application Note on Current Loop Calibration. Details calibration of controller powered, DC isolated current loops.
back to Literature Categories |
20. |
|
|
AN010-23_Fail_Safe_Chem_Feed.pdf |
Application Note on Fail Safe Acid & Oxidant Feeds. Details the installation of fail-safe hardware for acid & oxidant feeds.
back to Literature Categories |
23. |
|
|
AN010-24_NCCS-10K_Config.pdf |
Application Note on Loop Powered, Non-Contact Conductivity Measurement. Details the installation and operation of Part NCCS-10K, Loop powered, non-contact, conductvity sensor and sensor entry, Part Hdr_CN.
back to Literature Categories |
24. |
|
|
AN010-25_Time_Cycle_Config.pdf |
Application Note on Timed Cycling Special Control. Details the operation of the ‘TC’, Timed Cycling, chemical feed pump intermittent feed, special control.
back to Literature Categories |
25. |
|
|
AN010-26_Time_Modulation_Config.pdf |
Application Note on Time Modulation Special Control. Details the operation of the ‘TM’, Time Modulation, chemical feed pump duty cycle special control.
back to Literature Categories |
26. |
|
|
AN010-27_Fail_Safe_Acid_Feed.pdf |
Application Note on Redundant Acid OverFeed Protection. Details the installation of fail-safe hardware for acid pumps.
back to Literature Categories |
27. |
|
|
AN010-28_WM_Switching_Relay.pdf |
Application Note on Limiting Waste Water Volume. Details the installation of a latching relay for switching flow between a waste water plant and drain.
back to Literature Categories |
28. |
|
|
AN010-31_Powering_Current_Loops.pdf |
Application Note on Powering Current Loops. Details the wiring of a 4-20mA current loop powered by an 18-24VDC power cube located in the controller enclosure.
back to Literature Categories |
32. |
|
|
AN_T004.pdf |
Application Note on how to connect directly to a controller via Crossover cable.
back to Literature Categories |
33. |
|
|
AN_T005.pdf |
Application Note on Powering Thermal Flowswitches Connecting an Auxiliary DC Supply. Details using a 15VDC, 300mA supply to power a Flowline thermal flowswitch.
back to Literature Categories |
 |
Technical Manuals |
1. |
|
|
Aegis_Tech.pdf |
Technical Manual for Aegis Cooling Tower Controller. Discusses Installation, Configuration, Sensors, and Applications.
back to Literature Categories |
12. |
|
|
VB24_24VSupply.pdf |
Technical manual for the 'VB24: Voltage Booster 24V @ 80mA'. Discusses Overview, Installation, Cabling, and Specifications.
back to Literature Categories |
14. |
|
|
Driver_CII.pdf |
Technical manual for the Current Input Isolated driver card (Part: CII). Discusses Application, Installation, Configuration, Operation, and Specifications.
back to Literature Categories |
15. |
|
|
AEGIS_modbus.pdf |
Aegis MODBUS Manual.
back to Literature Categories |
16. |
|
|
AEGIS_AD Alarm_Relay_Card.doc |
Operation, wiring, and installation guide for the Aegis Alarm Relay Card
back to Literature Categories |
17. |
|
|
AEGIS_AD Alarm_Relay_Card.pdf |
Operation, wiring, and installation guide for the Aegis Alarm Relay Card
back to Literature Categories |
 |
Backplane Drawings |
Please call (800) 909-9283 or email support@aquatrac.com to request Backplane Drawings for the Aegis product.
|
 |
Header Drawings |
2. |
|
|
Hdr_CO_F.pdf |
Sensor Installation Header for Conductivity, Temperature, and Flowswitch.
back to Literature Categories |
3. |
|
|
Hdr_CO_OR_CR_F.pdf |
Sensor Installation Header for Conductivity, Temperature, ORP, Corrosion Rate, and Flowswitch
back to Literature Categories |
4. |
|
|
Hdr_CP_CR_F.pdf |
Sensor Installation Header for Conductivity, Temperature, pH, Corrosion Rate, and Flowswitch
back to Literature Categories |
5. |
|
|
Hdr_CP_F.pdf |
Sensor Installation Header for Conductivity, Temperature, pH, and Flowswitch
back to Literature Categories |
6. |
|
|
Hdr_CP_FF_HP.pdf |
Sensor Installation Header for Conductivity, Temperature, and Flat-faced double junction pH
back to Literature Categories |
7. |
|
|
Hdr_CP_OR_CR_F.pdf |
Sensor Installation Header for Conductivity, Temperature, pH, ORP, Corrosion Rate, and Flowswitch
back to Literature Categories |
8. |
|
|
Hdr_CP_OR_F.pdf |
Sensor Installation Header for Conductivity, Temperature, pH, ORP, and Flowswitch
back to Literature Categories |
9. |
|
|
Hdr_OR.pdf |
Sensor Installation Header for ORP Sensor and Solution Ground
back to Literature Categories |
10. |
|
|
Hdr_OR_F.pdf |
Sensor Installation Header for ORP Sensor and Flowswitch
back to Literature Categories |
11. |
|
|
Hdr_PH.pdf |
Sensor Installation Header for pH Sensor and Solution Ground
back to Literature Categories |
12. |
|
|
Hdr_PH_F.pdf |
Sensor Installation Header for pH Sensor and Flowswitch
back to Literature Categories |
 |
Upgrade Manuals |
Please call (800) 909-9283 or email support@aquatrac.com to request Upgrade Manuals for the Aegis product.
|
 |
|
|
Part # |
Description |
Analog Sensors |
 |
7760475 |
High Pressure ORP sensor, 200PSI, ambient temp rating, 3/4” NPT |
 |
7760320 |
ORP Electrode, flat faced double junction 100 PSI @ 175oF |
 |
7760197 |
ORP Electrode, Red, 1/2” Diameter. 100 PSI @ 175oF |
 |
7760476 |
High Pressure pH sensor, 200PSI, ambient temp rating, 3/4” NPT |
 |
7760195 |
pH Electrode, flat faced double junction 100 PSI @ 175oF |
 |
7760474 |
Amplified 12mm, blue pH sensor, One (1) year life. 100PSI @ 175oF |
 |
7760200 |
Conductivity Electrode. 125PSI @125°f, with ‘Tee’ |
 |
7760193 |
Conductivity electrode. 3/4in NPT. 250psi Steam Max. |
 |
7760002 |
Conductivity electrode. 3/4in NPT. 250psi Steam Max. |
 |
7760002 |
Conductivity Boiler Sensor. 3/4in NPT w/ Conduit Box. 25ft wire. 250psi Steam Max. |
 |
7760005 |
High Pressure Conductivity electrode, 3/4in NPT, 350psi Max. |
 |
7760191 |
Conductivity electrode. Hot water conductivity or 250psi Max, For temp display. |
 |
7760192 |
Conductivity electrode. Hot water conductivity or 250psi Max. |
 |
7760465 |
pH electrode, Condensate rated, 1/2in NPT stainless steel, AS & FLEX Series. |
 |
7760175 |
Aquatrac Thermal Flow Switch 100PSI @ 125oF |
 |
7760021 |
Aquatrac Conductivity/Temperature/Thermal Flow Switch |
 |
7760203 |
High Pressure Flow Switch, 1.5GPM, 400PSI max, 3/4” NPT, Bronze |
 |
7760201 |
Magnetic plunger type Flow Switch, 1.5GPM, 100PSI max, 3/4in NPT |
 |
Water Meters |
 |
7760518 |
3/4” Contacting head water meter, 1GPC, 3/4” FNPT |
 |
7760515 |
1” Contacting head water meter, 10GPC, 1” FNPT |
 |
7760516 |
1 1/2” Contacting head water meter, 100 GPC, 1” FNPT |
 |
7760517 |
2” Contacting head water meter, 1GPC, 2” FNPT |
 |
7760514 |
3/4in Paddlewheel Water Meter Sensor. Supplied in PVC pipe section. |
 |
7760508 |
1in Paddlewheel Water Meter Sensor. Supplied in PVC pipe section. |
 |
7760509 |
1.5in Paddlewheel Water Meter Sensor. Supplied in PVC pipe section. |
 |
7760510 |
2in Paddlewheel Water Meter Sensor. Supplied in PVC pipe section. |
 |
7760511 |
3in Paddlewheel Water Meter Sensor. Supplied in PVC pipe section. |
 |
7760512 |
4in Paddlewheel Water Meter Sensor. Supplied in PVC pipe section. |
 |
Solenoids and Valves |
 |
7760217 |
Motorized blowdown valve, 1/2in NPT, 120VAC, rated 250psi steam |
 |
7760006 |
Needle valve 1/2in, rated 250psi steam, color coded shaft, numbered handle |
 |
7760109 |
Orifice Union, 1/2in NPT, 250psi steam, with four orifice plates |
 |
 |
-
Analog and Digital I/O
-
Conductivity Sensor:
Tower, Boiler, Condensate & Integral Flowswitch sensors
Default tower sensor includes 1GPM integral flowswitch
-
Fixed Temperature Sensor Input
Thermal compensation for both pH and Conductivity
Displayed as F, C or K
-
Fixed 4-20mA Current Loop input
Assignable to control any relay or variable frequency control
Single point calibration if 4mA=0
-
4 Optional analog inputs/outputs
Choose from the following; conductivity with temperature, pH/ORP, 4-20mA input, 4-20mA output, corrosion rate and boiler conductivity.
Each optional current output uses a dual sensor card slot
-
7 max. Manual-Inventory-ppm Inputs
Track drop counts, inventory, tank level, ppm
Alarmed Delay prevents premature system alarms
-
Communications User Interface
-
Keypad - LCD
5 key tactile feedback, universal characters, 2 line, backlit
Scan rate 100 mS nominal
-
10Base T, TCP/IP Ethernet LAN (optional)
HTML, Micro Web Server with user definable IP address
Static IP
-
10Base T, TCP/IP Ethernet LAN (optional)
HTML, Micro Web Server with user definable IP address
Browser shows controller in real time
-
Controls
-
Sequential Volume Setpoints
Feed a fixed volume for every make-up volume
Meter only, fault tolerant feed controls
-
Blocking
Any of 8 controls may block any other control
Prevents incompatible concurrent controls
-
Interlocking
Up to 4 contact sets can be ‘AND’ed or ‘OR’ed
Relays & Frequency controls OFF when contact set opens
-
9 Biocide Event Controls
Each of 9 controls includes 28 timed events
Each control selectable for 1,7 & 28 day cycles
-
System
-
Power
120 or 230VAC, 50/60 Hz
Line voltage selectable
-
Fusing for 5 AC powered loads
5 Amps @ 120VAC or 2.5Amps @ 230VAC
Alarm on open AC load fuse
-
Surge Suppression
Relay 2-5 N.O. contacts snubbed @ 0.1uF, 150 ohm
Varistor on AC line input
-
Accessory Power
15-22VDC, Unregulated, Thermally Fused @ 50mA
Auto-recovery on fault cleared.
-
Enclosure
Non-metallic, NEMA4X
7.5” W x 11.3” H x 5.5” D (190mm W x 287mm H x 140mm D)
-
Certifications
-
CSA (Pending):
CSA tested to comply with UL
|