Multiflex Literature |
User Manuals |
1. |
|
|
M714_User_Multiflex_portugues.pdf |
Multiflex Manual de Instrucciones
back to Literature Categories |
31. |
|
|
M714_User.pdf |
User Manual for the Multiflex controller. Discusses Installation, Operation, Wiring, Configuration, and Maintenance.
back to Literature Categories |
32. |
|
|
M714_Browse.pdf |
User Manual for the Multiflex controller. Discusses how to use the Multiflex Browser for viewing controller status and controller configuration.
back to Literature Categories |
33. |
|
|
Driver_B.pdf |
User Manual for the 'B Driver' card (The 'B Driver' card measures one or two Conductivity sensors). Discusses Installation, Configuration, and Specification on the B Driver.
back to Literature Categories |
34. |
|
|
Driver_CI.pdf |
User Manual for the 'CI Driver' card (The 'CI Driver' card measures two 4-20mA Current Loop Inputs). Discusses Installation, Configuration, and Specification on the CI Driver.
back to Literature Categories |
35. |
|
|
Driver_CR.pdf |
User Manual for the 'CR Driver' card (The 'CR Driver' measures one or two corrosion rates using Linear Polarization Resistance). Discusses Installation, Configuration, and Specification on the CR Driver.
back to Literature Categories |
36. |
|
|
Driver_CT.pdf |
User Manual for the 'CT Driver' card (The 'CT Driver' measures conductivity and temperature, connecting to a single immersed sensor). Discusses Installation, Configuration, and Specification on the CT Driver.
back to Literature Categories |
37. |
|
|
Driver_IO.pdf |
User Manual for the 'IO Driver' card (The 'IO Driver' provides one or two, DC isolated, loop powered 4-20mA outputs). Discusses Installation, Configuration, and Specification on the IO Driver.
back to Literature Categories |
38. |
|
|
Driver_OP.pdf |
User Manual for the 'OP Driver' card (The 'OP Driver' measures ORP and pH sensors). Discusses Installation, Configuration, and Specification on the OP Driver.
back to Literature Categories |
39. |
|
|
Driver_PT.pdf |
User Manual for the 'PT Driver' card (The 'PT Driver' measures a pH sensor and a temperature using a platinum RTD.). Discusses Installation, Configuration, and Specification on the PT Driver.
back to Literature Categories |
40. |
|
|
Driver_RS.pdf |
User Manual for the 'RS Driver' card (The 'RS Driver' measures flow rate using a turbine or paddlewheel water meter and may be configured to control the stroke rate of a solenoid drive chemical feed pump based on the measured flow rate). Discusses Installation, Configuration, and Specification on the RS Driver.
back to Literature Categories |
41. |
|
|
Driver_OP_Ext.pdf |
User Manual for the 'OP_Ext Driver' card (The 'OP_Ext Driver' measures a remote pH sensor connected to a Multiflex, Aegis, or SmartSeries (Flex/AS) controller). Discusses Installation, Configuration, and Specification on the OP_Ext Driver.
back to Literature Categories |
|
Application Notes |
1. |
|
|
HowToSetupComputerIPAddress.pdf |
(Adobe PDF) Instructions on how to configure the IP Address of your computer so that you can communicate (via web browser and/or Trackster) with a controller.
back to Literature Categories |
2. |
|
|
AN_Calibrate_4-20mA.pdf |
Single point calibration of 4-20mA inputs
back to Literature Categories |
3. |
|
|
AN_CorrosionRate.pdf |
Verifying Corrosion Rate Measurement
back to Literature Categories |
4. |
|
|
AN010-01_Snubbers.pdf |
Application Note that explains what a ‘snubber’ is and why they are required on some blowdown valves to prevent controller resets and controller power relay failures.
back to Literature Categories |
5. |
|
|
AN010-02_Sensor_PM.pdf |
Application Note on Preventative Maintenance for Cooling Tower Sensors. Lists sensors with recommended calibration, cleaning and replacement schedules
back to Literature Categories |
6. |
|
|
AN010-03_ORP_Sensor_Test.pdf |
Application Note on ORP Sensors Electrical Testing. Details electrical testing to identify ORP sensor failures
back to Literature Categories |
12. |
|
|
AN010-09_Paddle_Flowswitch.pdf |
Application Note which Provides source and part number information for the older, 1/2in NPT paddle type flow switches Aquatrac Part Number A261400; used in Smart3 and earlier version of S1T series controllers.
back to Literature Categories |
16. |
|
|
AN010-16_4-20mA_Troubleshooting.pdf |
Application Note on Current Loop Function and Troubleshooting. Discusses the troubleshooting self powered, DC isolated current loops.
back to Literature Categories |
17. |
|
|
AN010-17_4-20mA_Loop_Calib.pdf |
Application Note on Current Loop Calibration. Details calibration of controller powered, DC isolated current loops.
back to Literature Categories |
20. |
|
|
AN010-23_Fail_Safe_Chem_Feed.pdf |
Application Note on Fail Safe Acid & Oxidant Feeds. Details the installation of fail-safe hardware for acid & oxidant feeds.
back to Literature Categories |
22. |
|
|
AN010-24_MultiFlex Toroidal.pdf |
Application Note on Loop Powered, Non-Contact Conductivity Measurement for Multiflex controllers. Details the installation & operation of Part NCCS-10K, Loop powered, non-contact, conductvity sensor & sensor entry, Part Hdr_CN.
back to Literature Categories |
23. |
|
|
AN010-24_NCCS-10K_Config.pdf |
Application Note on Loop Powered, Non-Contact Conductivity Measurement. Details the installation and operation of Part NCCS-10K, Loop powered, non-contact, conductvity sensor and sensor entry, Part Hdr_CN.
back to Literature Categories |
24. |
|
|
AN010-25_Time_Cycle_Config.pdf |
Application Note on Timed Cycling Special Control. Details the operation of the ‘TC’, Timed Cycling, chemical feed pump intermittent feed, special control.
back to Literature Categories |
25. |
|
|
AN010-26_Time_Modulation_Config.pdf |
Application Note on Time Modulation Special Control. Details the operation of the ‘TM’, Time Modulation, chemical feed pump duty cycle special control.
back to Literature Categories |
26. |
|
|
AN010-27_Fail_Safe_Acid_Feed.pdf |
Application Note on Redundant Acid OverFeed Protection. Details the installation of fail-safe hardware for acid pumps.
back to Literature Categories |
27. |
|
|
AN010-28_WM_Switching_Relay.pdf |
Application Note on Limiting Waste Water Volume. Details the installation of a latching relay for switching flow between a waste water plant and drain.
back to Literature Categories |
28. |
|
|
AN010-31_Powering_Current_Loops.pdf |
Application Note on Powering Current Loops. Details the wiring of a 4-20mA current loop powered by an 18-24VDC power cube located in the controller enclosure.
back to Literature Categories |
29. |
|
|
AN_Password_Security.pdf |
Application Note on how to lockout logging-on after invalid passwords. MultiFlex controllers with firmware versions starting at T036 can be set to lockout Modem, Trackster and Browser access after 5 incorrect passwords on any combination of user ids.
back to Literature Categories |
30. |
|
|
AN_T001.pdf |
Application Note on the Multiflex CS Command. This document specifies the definitions of the result set of a Telnet CS command.
back to Literature Categories |
31. |
|
|
AN_T003.pdf |
Application Note on the Multiflex Telnet and URL commands for controller communications.
back to Literature Categories |
32. |
|
|
AN_T004.pdf |
Application Note on how to connect directly to a controller via Crossover cable.
back to Literature Categories |
33. |
|
|
AN_T005.pdf |
Application Note on Powering Thermal Flowswitches Connecting an Auxiliary DC Supply. Details using a 15VDC, 300mA supply to power a Flowline thermal flowswitch.
back to Literature Categories |
34. |
|
|
AN_T009.pdf |
Application Note on High Temperature LCD Displays. Above 115F, 46C, the LCD display will darken and become unusable. This application note AN_T009 details the LCD display upgrade sequence.
back to Literature Categories |
35. |
|
|
AN_T011.pdf |
Application Note on Sharing a phone line among 2 or more controllers. Details how Two or more Aquatrac controllers with modems can share a common phone line using a commercially available phone switch.
back to Literature Categories |
36. |
|
|
XML History Format r0.2.doc |
Specification for the Multiflex XML historical data format. [DOC]
back to Literature Categories |
37. |
|
|
XML History Format r0.2.pdf |
Specification for the Multiflex XML historical data format. [PDF]
back to Literature Categories |
|
Technical Manuals |
2. |
|
|
Driver_B.pdf |
Technical Manual for Boiler Condensate Conductivity
back to Literature Categories |
3. |
|
|
Driver_CI.pdf |
Technical Manual for Current Input (4-20mA Input) Driver
back to Literature Categories |
4. |
|
|
Driver_CR.pdf |
Technical Manual for Corrosion Rate Driver
back to Literature Categories |
5. |
|
|
Driver_CT.pdf |
Technical Manual for Conductivity / Temperature Driver
back to Literature Categories |
6. |
|
|
Driver_IO.pdf |
Technical Manual for 4-20mA Output Driver
back to Literature Categories |
7. |
|
|
Driver_OP.pdf |
Technical Manual for pH / ORP Driver
back to Literature Categories |
8. |
|
|
Driver_RS.pdf |
Technical Manual Rate-Input Stroke-Output Driver
back to Literature Categories |
12. |
|
|
VB24_24VSupply.pdf |
Technical manual for the 'VB24: Voltage Booster 24V @ 80mA'. Discusses Overview, Installation, Cabling, and Specifications.
back to Literature Categories |
13. |
|
|
M714_Tech.pdf |
Technical manual for the M5 and M10 (aka M7 and M14) Multiflex Controller. Discusses Installation, Wiring/Cabling, LAN Communications, Control Configuration, Sensors, and more.
back to Literature Categories |
14. |
|
|
Driver_CII.pdf |
Technical manual for the Current Input Isolated driver card (Part: CII). Discusses Application, Installation, Configuration, Operation, and Specifications.
back to Literature Categories |
|
Backplane Drawings |
Please call (800) 909-9283 or email support@aquatrac.com to request Backplane Drawings for the Multiflex product.
|
|
Header Drawings |
1. |
|
|
HDR-CP-OR-F.pdf |
Typical Installation Piping (part HDR-CP-OR-F)
back to Literature Categories |
2. |
|
|
Hdr_CO_F.pdf |
Sensor Installation Header for Conductivity, Temperature, and Flowswitch.
back to Literature Categories |
3. |
|
|
Hdr_CO_OR_CR_F.pdf |
Sensor Installation Header for Conductivity, Temperature, ORP, Corrosion Rate, and Flowswitch
back to Literature Categories |
4. |
|
|
Hdr_CP_CR_F.pdf |
Sensor Installation Header for Conductivity, Temperature, pH, Corrosion Rate, and Flowswitch
back to Literature Categories |
5. |
|
|
Hdr_CP_F.pdf |
Sensor Installation Header for Conductivity, Temperature, pH, and Flowswitch
back to Literature Categories |
6. |
|
|
Hdr_CP_FF_HP.pdf |
Sensor Installation Header for Conductivity, Temperature, and Flat-faced double junction pH
back to Literature Categories |
7. |
|
|
Hdr_CP_OR_CR_F.pdf |
Sensor Installation Header for Conductivity, Temperature, pH, ORP, Corrosion Rate, and Flowswitch
back to Literature Categories |
8. |
|
|
Hdr_CP_OR_F.pdf |
Sensor Installation Header for Conductivity, Temperature, pH, ORP, and Flowswitch
back to Literature Categories |
9. |
|
|
Hdr_OR.pdf |
Sensor Installation Header for ORP Sensor and Solution Ground
back to Literature Categories |
10. |
|
|
Hdr_OR_F.pdf |
Sensor Installation Header for ORP Sensor and Flowswitch
back to Literature Categories |
11. |
|
|
Hdr_PH.pdf |
Sensor Installation Header for pH Sensor and Solution Ground
back to Literature Categories |
12. |
|
|
Hdr_PH_F.pdf |
Sensor Installation Header for pH Sensor and Flowswitch
back to Literature Categories |
|
Upgrade Manuals |